WEKO3
アイテム
痴呆診断における短期記憶および対光縮瞳反射に基づく方法の比較評価
http://hdl.handle.net/10649/543
http://hdl.handle.net/10649/543abf6758a-374d-4494-89b9-0e3fc01f5641
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | 紀要論文 / Departmental Bulletin Paper(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2011-02-15 | |||||
| タイトル | ||||||
| タイトル | 痴呆診断における短期記憶および対光縮瞳反射に基づく方法の比較評価 | |||||
| 言語 | ||||||
| 言語 | jpn | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | dementia | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | diagnosis | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | short-time memory | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | light reflex | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | HDS-R | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | departmental bulletin paper | |||||
| 著者 |
内山, 尚志
× 内山, 尚志× 史, 学敏× 福本, 一朗 |
|||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 2985 | |||||
| 姓名 | ウチヤマ, ヒサシ | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 2986 | |||||
| 姓名 | シ, ガクビン | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 2987 | |||||
| 姓名 | フクモト, イチロウ | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 2988 | |||||
| 姓名 | Uchiyama, Hisashi | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 2989 | |||||
| 姓名 | Shi, Xuemin | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 2990 | |||||
| 姓名 | Fukumoto, Ichiro | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Today Japan is rapidly becoming an aging society and the number of the old people with dementia is also increasing. Thus in future medical care for them will be taken at home. Caregivers must care for them in a proper way according to their severity of dementia. But there is no diagnose scales which caregivers can easily use. So an automatic dementia diagnose system and a system consists of an personal computer and a display with a touch pannel. Subjects memorize seven articles which have no relation each other on the display. After the seven articles are hidden, they recall and choose the same articles from twenty articles which contain previous seven articles. In experiments with 30 subjects, the correlation coefficient between the number of correct answers and the score of HDS-R was 0.866 and miss judge rate was 10%. The latter consists of a pen-light, an infrared camera, a digital video camera and a personal computer and evaluates the degree of dementia based on the motic time and healthy old people on the motic time (p<0.05) and between patients with healthy old people and AD (p<0.01) and patients with CVD (p<0.05) on the motic rate. The aim of this study is to compare these systems. 10 subjects were evaluated with these systems and HDS-R. The correlation coefficients between the two system s were 0.471 on the motic time and 0.382 on the motic rate. And the correlation coefficients with HDS-R were 0.933. on the automatic dementia diagnose system, 0.471 on the motic time and 0.382 on the motic rate. | |||||
| 書誌情報 |
長岡技術科学大学研究報告 巻 20, p. 65-71, 発行日 1999-02-10 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0388-5631 | |||||
| 書誌レコードID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AN00177120 | |||||
| 著者版フラグ | ||||||
| 出版タイプ | VoR | |||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
| その他のタイトル | ||||||
| その他のタイトル | An assessment of pupil reflex for light with the automated dementia diagnosis system | |||||
| 出版者 | ||||||
| 出版者 | 長岡技術科学大学 | |||||