WEKO3
アイテム
Purkinje-Sanson像による視力判定法の研究
http://hdl.handle.net/10649/591
http://hdl.handle.net/10649/591418971f4-c581-4554-b4a5-62624534a062
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| アイテムタイプ | 紀要論文 / Departmental Bulletin Paper(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2011-02-15 | |||||
| タイトル | ||||||
| タイトル | Purkinje-Sanson像による視力判定法の研究 | |||||
| 言語 | ||||||
| 言語 | jpn | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | myopia | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | self-treatment | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | visual acuity | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | refractive power | |||||
| キーワード | ||||||
| 主題Scheme | Other | |||||
| 主題 | Purkinje-Sanson images | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | departmental bulletin paper | |||||
| 著者 |
日吉, 功
× 日吉, 功× 児玉, 直樹× 和久井, 章人× 福本, 一朗 |
|||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 3324 | |||||
| 姓名 | HIYOSHI, Isao | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 3325 | |||||
| 姓名 | KODAMA, Naoki | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 3326 | |||||
| 姓名 | WAKUI, Akihito | |||||
| 著者別名 | ||||||
| 識別子Scheme | WEKO | |||||
| 識別子 | 3327 | |||||
| 姓名 | FUKUMOTO, Ichiro | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 著者所属 | ||||||
| 値 | 長岡技術科学大学生物系 | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Though there are many treatment methods of myopia, these methods cause side effects. We propose a new visual acuity test with Purkinje-Sanson (PS) images as the first step of the development of an invasive self-treatment method. The purpose of the present study is evaluate visual acuity by the distance between PS images. Fourteen patients (12 myopic and 2 emmetropic) were examined for visual acuity, refractive power and PS images. Visual acuity and refractive power were measured with Landoltis rings and a NIDEK AR-600A autorefractometer, respectively. PS images took a photograph with CCD camera. And the distance between PS1 and PS3 images were calculated. We found high correlation between the PS images distance and refractive power (r = -0.801) and cylinder power had no effect on the PS images distance. These results raise the possibility of a new visual acuity teat with PS images. | |||||
| 書誌情報 |
長岡技術科学大学研究報告 巻 23, p. 23-28, 発行日 2001-11-30 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0388-5631 | |||||
| 書誌レコードID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AN00177120 | |||||
| 著者版フラグ | ||||||
| 出版タイプ | VoR | |||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
| その他のタイトル | ||||||
| その他のタイトル | A study of visual acuity diagnosis by Purkinje-Sanson images | |||||
| 出版者 | ||||||
| 出版者 | 長岡技術科学大学 | |||||